型号 NE3-350-3.3 NES-350-5 NES-350-7.5 NES-350-12 NES-350-15 NES-350-24 NES-350-27 NES-350-36 NES-350-48
输出 直流电压 3.3V 5V 7.5V 12V 15V 24V 27V 36V 48V
额定电流 60A 60A 46A 29A 23.2A 14.6A 13A 9.7A 7.3A
嵬流范围 0-60A 0-60A 0-46A 0-29A 0-23.2A 0-14.6A 0-13A 0-9.7A 0-7.3A
额定功率 198W 300W 345W 348W 348W 350.4W 351W 349.2W 350.4W
纹波与噪声备w 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p 240mVp-p
电压调整范围 2.97-3.7V 4.5-5.6V 6-9V 10-13.5V 13.5-18V 20 ~ 26.4V 26-32V 32 ~ 40V 41-56V
电压精度备注3 +3%,-4.5% ±3.0% +2.0% ±1.5% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
线性调整率 ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
负载调整率 ±2.5% ±2.0% +2.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
启动、上升时间 1000ms, 50ms/230VAC 1000ms,50ms/1 5VAC(满载时}
保持时间 20ms/230VAC 16ms/115VAC(满载时)
输入 电压范围备注4 90 - 132VAC /180 ~ 264VAC(通过开关切换} 254 ~ 370VDC
频率范围 47-63HZ
效率刚 74% 78% 180% 83% 84% 87% 88% 87.5% 87.5%
交流电流 7A/115VAC 4A/230VAC
浪涌电流 40A/115VAC 60A/230VAC
漏电流 <3.5mA/240VAC
保护 过负载 额定输出功率的105%~135%
保护模式:恒流限制,负载异常条件移除后可自动恢复
过电压 3.8~4.6V|5.75-7.5V 9.4-11.25V 13.8~16.2V 18-21V 27.6~32.4V 33.7-39.2V 41.4~46.8V 57.6-67.2V
保护模式:关断输出电压,重启恢复
过温度 90°C±5°C(3.3~7.5V);85°C±5°C(12~15V); 80°C±5°C(24V);75°C±5°C(27-48V) (TSW1 检测机壳温度)
保护模式:关断输出电压,温度下降后可自动恢复
功能 风扇开关控制(Typ.) RTH2^50°C 风扇启动,345。(:风扇关闭(3_3 - 7.5V)
RTH2255°C风扇启动,S50°C风扇关闭(12~48V)
环境 工作温度 -20?+60C (请参考负载减额曲线)
工作湿度 20~90%RH,无冷凝
储存温度、湿度 ■20-+85r,10~95% RH
温度系数 ±0_03%/°C(0 ?50°C)
耐振动 10~500啦,3610分钟/周期,义、Yv Z轴各60分钟
安规 安全规范 UL60950-1认证通过
耐压 l/P-0/P:3KVAC l/P-FG:1.5KVAC 0/P-F6;0.5KVAC
绝缘阻抗 l/P-O/P, l/P-FG, 0/P-FG:100M Ohms 1500VDC / 251C/70% RH
其它 MTBF >234.3Khrs. MIL-HDBK-217F(25°C)
尺寸 215*115*50mm (L*W*H)
包装 1.07Kg;12pcs/13.5Kg/0.92CUFT