产品概述
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/57/57853c0c-cdc9-43c3-9205-9c687ddb1a3c.jpg)
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/e3/e3ab00c0-ce27-4950-ab72-a84754ccaea9.jpg)
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/6c/6c39aed9-15ea-48ce-8219-996198fcbec1.jpg)
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/d5/d5be903b-ec5f-483a-8d87-2e0608fb4005.jpg)
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/4b/4bdf604d-0dfc-46f1-8ee0-81698b76f0ac.jpg)
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/10/10c593ac-0bad-4b0b-8935-712f58857fe2.jpg)
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/b3/b34ad02a-e1e4-450f-8f28-1aaba95062b9.jpg)
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/13/1313cadb-2ded-40cf-83e8-3112a20cb1e2.jpg)
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/50/5078c2ce-d0ee-4b39-8c62-fa0d5bd3abd2.jpg)
![一二次融合断路器](http://docs.ebdoor.com/Image/InfoContentImage/ProductDesc/2018/05/22/87/8708b7ea-32fa-483e-b50b-9fb75d8785f2.jpg)
产品使用环境
序号
|
名 称
|
单位
|
标准参数值
|
1
|
周围空气温度
|
气温
|
℃
|
+40
|
气温
|
-40
|
日温差
|
K
|
25
|
2
|
海拔
|
m
|
≤1000
|
3
|
太阳辐射强度(户外)
|
W/cm2
|
0.1
|
4
|
污秽等级
|
|
Ⅳ
|
5
|
覆冰厚度
|
mm
|
10
|
6
|
风速/风压(户外)
|
(m/s)/Pa
|
34/700
|
7
|
湿度
|
日相对湿度平均值
|
%
|
≤95
|
月相对湿度平均值
|
≤90
|
8
|
耐受地震能力
|
水平加速度/垂直加速度
|
m/s2
|
0.3g/0.15g
|
正弦共振三周波,安全系数1.67以上
|
产品功能要求
1)一二次成套装置由开关关本、控制单元,电源电压互感器:连接电缆等构成。
2)开关本体应内置高精度,宽范国的电压/电流传感器满足故障检测,测量、计量等功能和计算线损的要求.
3)开关采用内置1组电压传感器,提供Ua,Ub,Uc,Uo(测量,计量)电压信号,内置1组电流传盛器、提供Ia,Ib,IC,Io(保护,测量,计量)电流信号,并外置2台电源电压互感器安装在开关两侧,线路有压信号取自电源电压互感器、
4)具备采集三相电流,三相电压、零序电流。零序电压的能力,满足计算有功功率、无功功率,功率因数、频率和计量电能量的功能。
5)具备相间故障处理和小电流接地系统单相接地故障处理功能,可直接跳闸切除故障,具备目动重合闸功能,重合次数及时同可调。