北京市北方思源电子技术中心
诚信指数 0
一站通留言 客户留言 联系我们 联系我们 收藏此网站 发送消息
首页
企业名片
企业介绍
资质荣誉
产品列表
商业信息
企业新闻
招聘信息
客户留言
search 搜索网站中其它产品:
一比多
您现在的位置:北京市北方思源电子技术中心 > 产品列表
 
手机综测仪 HP8922M+83220E

价        格:面议   
产品型号: HP8922M+83220E
有 效 期: 长期有效
所 在 地: 北京市海淀区
配送信息:
供应数量:不限
了解详情,请立即咨询!
 

   
      20  21  22  23  24  25  26  27  28  29  
该公司共有 29条同类“无线电综测仪”信息       查看全部>>
详细说明

无线电综测仪 HP8922M+83220E

GSM Mobile Station Test Set

厂家: 美国惠普
尺寸: 44x31x61cm
重量: 48 kg

性能指标pdf

频率分辨率:1Hz(跳跃模式中为100MHz) 转换速度:557μs
相关数据解调:0.3GMSK在270.833kb/s上,1时隙/帧 模拟解调:调频和脉冲
综合方法: rms和峰值相位误差、频率误差 幅度包络:上升、下降和有用比特上的突发平整度损坏 发射机峰值功率:+10dBm~+45dBm,(-5dBm~41dBm,Agilent 8922F/H)
输出射频频谱测量1:取决于调制和争换的瞬变过程

  • RF Generator
    Frequency Range: 10 MHz to 1000 MHz
    Frequency Resolution: 1 Hz
    Switching Speed: 577us
    0.3 GMSK Modulation: External clock and data
    Pulse Modulation: Normal and 30dB
    Output Power: -14 to -127 dBm
  • Spectrum Analyzer (Option 006)
    Frequency Range: 10 MHz to 1000 MHz
    Frequency Accuracy and Stability: Same as timebase
    Display Range: 80 dB
    Other Features: External trigger, marker
    Digital Oscilloscope
    Frequency Range: 2 Hz to 50 kHz
    Sweep Times: 10us to 100 ms in 1,2,5,10 steps
    Audio Analyzer
    Frequency Range: 20 Hz to 400 kHz
    AC Voltage Range: 0 to 30 Vrms
    DC Voltage Range: 100 mV to 42 V
    THD + Noise: 1 kHz ± 5 Hz
    SINAD: 1 kHz ± 5 Hz
    Audio Source
    Frequency Range: DC to 25 kHz
    Output Level Range: 0.1 mVrms to 4 Vrms

The combination of HP 8922M with the HP 83220E and a new firmware forms a complete Dual-Band (GSM 900/ DCS 1800) Test Solution.
All original features are retained but now, with dual-band intra-cell handover capability, the newer GSM mobiles can be tested seamlessly, at all frequencies, through a single RF connector.

Description of HP 8922H/83220E:

The HP 8922H GSM Test Set (HP 8922M with opt. 010) is an integrated test solution for the production and servicing of GSM and DCS-1800 radios. The HP 8922H is a tool box with the necessary hardware to test the RF characteristic of GSM radios.
The HP 8922 contains a complete set of instrumentation for testing the RF sections of GSM radios. In addition to the frequency-agile 0.3 GSMK RF generator, the RF analyzer has an agile local oscillator, coherent data demodulator, pulse demodulator, FM demodulator, global method analyzer for phase and frequency error, synthesized spectrum analyzer (optional), and pulsed power meter.
The 8922 G adds a bit-error-rate tester (BERT) for performing GSM receiver measurements, channel CODEC for speech encoding and decoding, and call control protocol to set up a phone call and maintain the link while performing measurements. Echo mode is facilitated by the voice CODEC for functional testing of a mobile, and the electrical man-machine interface (EMMI) is implemented for controlling the mobile and supporting the digital audio interface (DAI).
Besides this complement of GSM-specific instruments, the HP 8922 contains general-purpose tools useful for module test, troubleshooting, and debugging activities. These tools include a digital oscilloscope, a CW RF frequency counter, a CW RF power meter, an AC voltmeter, a DC voltmeter, a 1 kHz distortion/SINAD meter, an audio frequency counter, and a synthesized audio source. The combination of these capabilities makes the HP 8922 an extraordinarily powerful tool for the manufacture and installation of GSM radio equipment.
Specifications:
RF Generator: Frequency range 10 MHz to 1000 MHz; resolution 1 Hz.
RF Analyzer: Frequency range 10 MHz to 1000 MHz; resolution 1 Hz (100 kHz in hop mode).
Spectrum Analyzer: Frequency range 10 MHz to 1000 MHz; display range: 80 dB (option 006 - NOT INCLUDED; available for extra charge)
Digital Oscilloscope: Frequency range 2 Hz to 50 kHz; sweep times 10 µs to 100 ms in 1, 2, 5, 10 steps
Audio Analyzer: Frequency range 20 Hz to 400 kHz
Audio Source: Frequency range DC to 25 kHz
Remote programming HPIB: IEEE488.2
Remote programming RS232: 300, 1200, 2400, 4800, 9600 and 19200 baud.

The HP 83220E DCS/PCS Test Set expands the capabilities of the HP 8922 to comprehensively test DCS 1800 and PCS 1900 equipment.
DCS 1800 mobile radios across the band 1805 MHz to 1880 MHz and PCS mobile radios across the band 1930 MHz to 1990 MHz.
The HP 83220E when configured with the HP 8922H can establish and maintain a DCS 1800/ PCS 1900 link. Once a link has been established, comprehensive tests can be run across the mobile DCS 1800/ PCS 1900 band, without interrupting that link.

推荐浏览
二手无线电综测仪 CMS50
二手无线电综测仪 CMS50
面议
函数/任意波发生器 Agilent 33250A
函数/任意波发生器 Agilent 33250A
面议
可编程高速脉冲信号发生器 HP8130A
可编程高速脉冲信号发生器 HP8130A
面议

免责声明:本商铺所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,一比多公司对此不承担任何保证责任。

友情提醒:为保障您的利益,降低您的风险,建议优先选择商机宝付费会员的产品和服务。


北京市北方思源电子技术中心    地址:海淀区大柳树路富海中心4号楼105室   邮政编码:100081
联系人:小孙   电话:010-62123259   手机:01062123259   传真:010-62123259
技术支持:一比多  |  免责声明 | 隐私声明
增值电信业务经营许可证:沪B2-20070060     网站Icp备案号:沪ICP备05000175号
<%---站点编号 ----%> <%---页面编号 ----%> <%---页面参数1 ----%> <%---页面参数2----%> <%---页面参数3 ----%>