Specifications
|
Model CVH
|
Model HATR-T2
|
Model CH
|
Working Platform
|
Cuvette Holder
|
Horizontal Platform
|
Card Reader
|
Min. Detection Limit
|
2 ppm
|
8 ppm
|
40 ppm
|
(Oil in water)
|
Min. Detection Limit
|
10 ppm
|
40 ppm
|
200 ppm
|
(TPH in soil)
|
Solvent
|
Perchloroethylene, Freon-113, S-316
|
Hexane, Pentane, Vertrel MCA
|
Hexane, Pentane, Vertrel MCA
|
Component Measured
|
Measures all hydrocarbons
|
Measures hydrocarbons with a boiling point higher than the solvent - volatile hydrocarbons will be evaporated along with the solvent
|
Measures hydrocarbons with a boiling point higher than the solvent - volatile hydrocarbons will be evaporated along with the solvent
|
Instrument Repeatability
|
±1 ppm
|
±2 ppm
|
±4 ppm
|
Typical Applications
|
Oil in Water/Wastewater
|
Oil in Water/Wastewater
|
Very high levels of Oil in Water
|
Oil in Produced Water
|
Oil in Produced Water
|
TPH in Soil
|
Fats, Oil & Grease (FOG in Wastewater Discharges)
|
Fats, Oil & Grease (FOG in Wastewater Discharges)
|
|
Oil in Frac Water
|
Oil in Frac Water
|
|
TPH in Soil
|
TPH in Soil
|
|
Samples with Light-End Volatile Components
|
|
|
Other Instructions
|
Solvents are heavier than water and require a separatory funnel or inverted vial with a septa cap to collect a solvent sample.
|
Solvents are lighter than water and solvent sample can be collected from the top of the container.
|
Solvents are lighter than water and solvent sample can be collected from the top of the container.
|
Ordering Information
|
InfraCal TOG/TPH Analyzers
|
405-1009
|
InfraCal IR Platform Analyzer, HATR-T2 Complete with HATR-T2 Stainless Steel Trough Sample Stage with Built-in Cubic Zirconia ATR Crystal, Power Supply and Instruction Manual.
|
405-0003
|
InfraCal Cuvette Holder Analyzer, Model CVH Complete with CVH Sample Stage for use with 10 mm Quartz Cuvette Cells, Power Supply and Instruction Manual.
|
405-0002
|
InfraCal Card Reader Analyzer, Model CH Complete with CH Sample Stage for use with InfraCal Reusable IR Sample Plates with Sapphire Window, Power Supply and Instruction Manual.
|
Sample Handling Accessories
|
403-0012
|
Set of 4-10mm Quartz Cuvette Cells with Teflon stopper for use with Model CVH
|
403-0010/5
|
InfraCal Reusable IR Sample Plates with Sapphire Window, Set of 5 for use with Model CH
|
Accessories
|
403-0018
|
InfraLog Serial Printer Prints calibration and measurement data, complete with sequence number, date and time. Includes all required cables.
|
403-0013
|
Carrying Case with pre-diced pluck foam. 18.5x14.6x8", 10 lbs.
|
403-0002
|
Cigarette Lighter Adapter Cable
|
403-0005
|
Dust Cover
|
Field Sampling Kits
|
403-1010
|
Field Sampling Kit for TPH in Soil
|
403-1011
|
Field Sampling Kit for TOG in Water
|
403-1063
|
Field Sampling Kit for TOG in Water
|
Replacement Parts
|
403-0001
|
Universal Switching Power Supply and Line Cord for use with InfraCal Analyzers. 90-264 VAC, 50-60 Hz input, regulated 12v/25 watt output.
|
403-0014
|
Replacement Source/Cable Assembly
|
Additional One and Two Year Extended Factory Warranties
|
EWOY
|
Extended Factory Warranty for additional One Year (total two year factory warranty from date of shipment).
|
EWTY
|