ITEM |
VIP CONDUCTIVE TILE 2.0㎜ 3.0㎜ |
VIP STATIC-DISSIPATIVE TILE 2.0㎜ 3.0㎜ |
|
CEN CLASSIFICATION EN685 |
Class 34+43 |
Class 34+43 |
|
THICKNESS EN428 |
2.0㎜,3.0㎜ |
2.0㎜,3.0㎜ |
|
SIZE EN427 |
610㎜×610㎜ micro-squared |
610㎜×610㎜ micro-squared |
|
WEIGHT/M2 EN430 |
3.2kg(2.0㎜) 5.4kg(3.0㎜) |
3.2kg(2.0㎜) 5.4kg(3.0㎜) |
|
ELECTRICAL RESISTANCE DIN 51953 ASTM F-150 or NFPA99 |
104to106Ohm |
106to108Ohm |
STATIC GENERATION AATCC-134 |
Less than 100 volts with conductive footwear per AATCC-134 AT 20% relative humidity. |
Less than 300 volts with conductive footwear per AATCC-134 AT 20% relative humidity. |
STATIC DECAY Federal Test Method 101, Method 4046 |
5,000volts to zero in less than 0.03 seconds per Federal Test Method 101,Method 4046 at 15% relative humidity. |
5,000volts to zero in less than 0.2 seconds per Federal Test Method 101,Method 4046 at 15% relative humidity. |
|
HEAT RESISTANCE DIN 51612 |
0.00618m2k/w(2.0㎜) |
0.00618m2k/w(2.0㎜) |
|
THERMAL CONDUCTIVTY DIN51612 |
0.309W/m.k |
0.309W/m.k |
|
FIRE RESISTANCE DIN4102 |
B1 |
B1 |
Critical Radiant Flux ASTM E-648 or NFPA 253 |
>1.08W/㎝2(ClassⅠInterior Floor Finish,NFPA Life Safety Code 101) |
>1.08W/㎝2(ClassⅠInterior Floor Finish,NFPA Life Safety Code 101) |
Flame Spread ASTM E-84 or NFPA 225 |
<75 |
<75 |
Smoke Density ASTM E-662 |
<450 |
<450 |
|
ABRASION RESISTANCE ASTM D-1044,CS-10-F Wheel,500Gm Weight |
Cycles %Gauge Loss 2,500 .40 5,000 .80 7,5000 1.20 10,000 1.60 |
Cycles %Gauge Loss 2,500 .40 5,000 .80 7,5000 1.20 10,000 1.60 |
RESISTANCE TO WEAR EN660-1/DIN 51963 |
M |
M |
|
RESIDUAL INDENTATION EN433/DIN51955 |
0.03㎜(2.0㎜) 0.04㎜(3.0㎜) |
0.03㎜(2.0㎜) 0.04㎜(3.0㎜) |
|
DIMENSIONAL STABILITY EN434 |
≥0.10% |
≥0.10% |
|
EFFECT OF CASTOR CHALR EN425 |
No damage |
No damage |
|
COLOR FASTNESS ISO 105 B02 |
At least 6 |
At least 6 |
|
IMPACT SOUND ABSORPTION Vil,ISO140,ISO717 |
approx 2dB |
approx 2dB |
|
RESISTANCE TO CHEMICALS DIN423/DIN51958 |
Offers good resistance,see special sheet |
Offers good resistance,see special sheet |
|
REPAIRABLE |
Yes |
Yes |
|
STANDARD FOR HEALTH CARE FACILTIES NFPA 99 |
Confirms to the requirement of NFPA 99 in effect at the time of installation |
|
|
Fulfils product requirements EN 649 |
Yes |
Yes |
|
UNDERWRITERS LABORATORIES |
Meets UL Standard 779,"Standard for Electrically Conductive Flooring,"and is UL listed. |
|
|
Care and Maintenance |
See special sheet |
See special sheet |