Model Name : YH6421-1AXR
Mini Redundant Series 420 watts
● 185 (L) x 150 (W) x 84(H) mm ● High Power Density - 2.95 W/in3 ● Efficiency:≧ 65% at Max load of 115 ~ 230VAC ● Remote On/Off Control ● Current share with O-ring diodes ● RoHS compliant for all six substances
|
|
| |
|
|
|
|
|
|
Input Voltage Input Frequency Input Current
Inrush Current
Power Factor
Earth Leakage Current |
|
90 - 264VAC 47 - 63 Hz 7A max at 115V 3.5A max at 230V 60A max at 115V 120A max at 230V >0.95 / 115V 60Hz >0.93 / 230V 50Hz 3.5mA max at 264VAC / 50Hz | |
|
|
|
Efficiency Power Density Signals MTBF
Fault Indication |
|
Min 65% at 115VAC 2.95 W/in3 Power good, TTL compatible 100 kHrs per Bellcore SR-332 ISSUE1 at 25°C ambient Audible alarm, turned on by active high TTL, Visual-alarm, LED active | |
|
|
|
| |
|
|
Output Voltage Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Over / Undershoot Transient Response
Over Voltage Protection
Over Temperature Protection
Over Current Protection
Short Circuit Protection Temperature Coefficient Remote On/Off
Current Share |
|
See table See table < 500mSec maximum < 50mSec measured at 10% to 90% 16 mS/110V < 10% max at turn on/off < 4% max diviation, recovery to within 1% in 1mSec for 25%load change +3.3V:4.0V ~ 4.6V +5V:5.74V ~ 6.8V +12V:13.4V ~ 15.6V Latch-style Primary & secondary protection with auto recovery 110 - 150%, auto recovery upon removal of overload condition No damage,resistance ≦ 0.01Ω ≦0.05% per°C after 30min. operating On = PSON ≦ 0.8V, low Off = PSON ≦ 2.4V, high, open 2 supplies to share within ± 5% | |
|
| |
|
|
|
Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Remote sensing Shock Operating Non-Operating Vibration Operating Non-Operating |
|
0 to 40°C 18 CFM airflow required 5 - 90%, Non-condensing -40°C to +70°C Sea level to 7,000 feet +3.3V, +5V, +12V & -12V 5G, 11mSec, half sine 3 axes 30G, 11mSec, half sine 3 axes 0.5G, 10 Hz to 500 Hz, 3 axes 2G, 10 Hz to 300 Hz, 3 axes | |
|
|
|
|
Emissions
Harmonic Currents Voltage Flicker EFT/Burst Surge Conducted Immunity Safety Approvals |
|
EN55022, class B Conducted EN55022, class A Radiated EN61000-3-2, class D EN61000-3-3 EN61000-4-4, level 3 Perf Criteria B EN61000-4-5, level 3 Pref Criteria B EN61000-4-6, 10Vrms, Pref Criteria A UL/cUL60950-1, TUV, CB Report | |
|
| | |
|
Output |
Minimum Load |
Maximum Load |
Condition |
Ripple & Noise |
+3.3V |
0A |
20A |
Combined +3.3V & 5V power ≦191W
Combined +3.3V, +5V, +12V, -12V & +5VSB power ≦420W | |
50mV p-p |
+5V |
2A |
25A |
50mV p-p |
+12V |
0.5A |
20A |
120mV p-p |
-12V |
0A |
0.5A |
150mV p-p |
+5VSB |
0A |
2A |
50mV p-p | |
|
|
|
|
|