Output Voltage Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Over/Undershoot
Transient Response
Over Voltage Protection
Over Temperature Protection
Over Current Protection
Short Circuit Protection Temperature Coefficient Remote On/Off |
|
See table See table < 500 mSec maximum 1mSec to 50mSec measured from 10% to 90% > 17 mS/110V <10% max at tum on/of, recover within 50mS < 4% max diviation, recovery to within 1% in 1 mSec for 25% load change +3.3V:3.6V ~ 4.4V +5V:5.58V ~ 6.82V +12V:13.14V ~ 16.06V Primary & secondary protection with auto recovery +3.3V:30.8A ~ 42A +5V:33A ~ 45A +12V:22A ~ 30A No damage, resistance ≦0.01Ω ≦0.05%/°C after 30 min operating On = PSON ≦0.8V Off = PSON ≧2.4V, open | |
|
| |
|
|
|
Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Shock Operating Non-Operating Vibration Operating Non-Operating |
|
0 to 40°C 80mm fan required 5 - 90%, Non-condensing -40°C to +70°C sea level to 7,000 feet 5G, 11 mSec, half sine 3 axes 30G, 11 mSec, half sine 3 axes 0.5G, 10 Hz to 500 Hz, 3axes 2G, 10 Hz to 300 Hz, 3axes | |
|
|
|
|
Emissions
Harmonic Currents Voltage Flicker EFT/Burst Surge Conducted Immunity Safety Approvals |
|
En55022, class B Conducted En55022, class B Radiated EN61000-3-2, Class D EN61000-3-3 EN61000-4-4, level 3 Perf Criteria B EN61000-4-5, level 3 Perf Criteria B EN61000-4-6, 10Vrms Perf Criteria A UL/cUL60950-1, TüV, CCC, BSMI, CB Report | |
|
| |