Model Name : YH8132-2AXR
3U Redundant Series 1300 watts
● 350 (L) x 54.5 (W) x 128.3(H) mm ● Ultra compact Design (1/2U Width, 3U Height) ● Very High Power Density - 8.70 W/in3 ● Efficiency:≧ 80% at Max load of 115 ~ 230VAC ● low noise design ● Remote On/Off Control (TTL) ● Current share with O-ring diodes ● Tylersburg compliant ● I2C Serial Bus Interface (PSMI) ● RoHS compliant for all six substances
|
|
| |
|
|
|
|
|
|
Input Voltage Input Frequency Input Current
Inrush Current
Power Factor
Earth Leakage Current |
|
90 - 264VAC 47 - 63 Hz 8A max at 115V per module 4A max at 230V per module 40A max at 115V per module 60A max at 230V per module > 0.98 / 115V 60Hz > 0.94 / 230V 50Hz 3.5mA max at 264VAC / 50Hz | |
|
|
|
Efficiency Power Density Signals
MTBF
Remote Sensing Fault Indication |
|
Min 80% at 115VAC 8.70 W/in3 Power good, TTL compatible Alarm mute, i2c (PSMI) 100 kHrs per Bellcore SR-332 ISSUE1 at 25°C ambient +3.3V, +5V, +12V PSAlert# Visual alarm, LED Audible alarm, Buzzer | |
|
|
|
| |
|
|
Output Voltage Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Over / Undershoot Transient Response
Over Voltage Protection
Over Temperature Protection
Over Current Protection
Short Circuit Protection Temperature Coefficient Remote On/Off
Current Share |
|
See table See table < 500mSec maximum < 50mSec measured at 10% to 90% 17ms/110V < 10% max at turn on/off < 4% max diviation, recovery to within 1% in 1mSec for 25%load change +3.3V:3.9V ~ 4.5V +5V:5.7V ~ 6.5V +12V:13.3V ~ 14.5V Primary & secondary protection with latch off +3.3V:26.4A ~ 36A +5V:26.4A ~ 36A +12V1~3:33.89A ~ 46.2A No damage, resistance ≦ 0.01Ω ≦0.05% per °C On = PG ≦ 0.4V, low Off = PG ≦ 2.4V, high, open 3 supplies to share within ± 6.5% | |
|
| |
|
|
|
Operating Temperature Cooling Operating Humidity Storage Temperature Operating Altitude Shock Operating Non-Operating Vibration Operating Non-Operating |
|
0 to 40°C 15CFM airflow required 5 - 90%, Non-condensing -40°C to +70°C Sea level to 7000 feet 5G, 11mSec, half sine 3 axes 30G, 11mSec, half sine 3 axes 0.5G, 10 Hz to 500 Hz, 3 axes 2G, 10 Hz to 500 Hz, 3 axes | |
|
|
|
|
Emissions
Harmonic Currents Voltage Flicker EFT/Burst Surge Conducted Immunity Safety Approvals |
|
EN55022, class B Conducted EN55022, class B Radiated EN61000-3-2, class D EN61000-3-3 EN61000-4-4, level 3 Perf Criteria B EN61000-4-5, level 3 Pref Criteria B EN61000-4-6, 10Vrms, Pref Criteria A UL/cUL60950-1, TUV, CB, CE, CCC FCC Report | | | |
|
|
|
|