Output Voltage Minimum Load Start Up Delay Start Up Rise Time Hold Up Time Over / Undershoot Transient Response
Over Current Protection
Over Voltage Protection
Over Current Protection
Short Circuit Protection Over Temperature Protection |
|
See table See table max. 500mS max. < 50mS measured at 10% - 100% > 17ms < 10% max at turn on/off, recover within 50mS < 30% max diviation +3.3V:18.7A ~ 25.5A +5V:19.8A ~ 27A +12V:26.4A ~36A +3.3V:3.9V ~ 4.5V +5V:5.7V ~ 6.5V +12V:13.3V ~ 14.5V Primary & secondary protection with latch off +3.3V:110% - 150% +5V:110% - 150% +12V1~3:110% - 150% No damage, resistance ≦ 0.01Ω in case of Fan loose or excessive ambient temperature | |
|
| |
|
|
|
Operating Temperature Cooling Operating Humidity Storage Temperature Shock Operating Non-Operating Vibration Operating |
|
0 to 40°C 40mm FAN required 5 - 90%, Non-condensing -40°C to +70°C Sea level to 7,000 feet 5G, 11mSec, half sine 3 axes 30G, 11mSec, half sine 3 axes 0.5G, 10 Hz to 500 Hz, 3 axes 2G, 10 Hz to 500 Hz, 3 axes | |
|
|
|
|
Emissions
Harmonic Currents Voltage Flicker EFT/Burst Surge Conducted Immunity Safety Approvals |
|